EOS StainlessSteel 17-4PH
Material Data Sheet
EOS StainlessSteel 17-4PH
Precipitation hardening steels are widely used in engineering applications, which require corrosion resistance and strength. Parts built from EOS StainlessSteel 17-4PH can be machined, shot-peened and polished in as-built or heat treated states. Solution annealing together with ageing treatment are necessary in order to achieve proper hardness and mechanical properties (ASTM A564 – 13). Due to the layerwise building method, the parts have a certain anisotropy which can be eased by solution annealing.
- Corrosion resistance and strength
- Parts can be machined, shot-peened and polished in asbuilt or heat treated states
- Solution annealing together with aging treatment are necessary in order to achieve proper hardness and mechanical properties (ASTM A564-13)
- Chemical composition and part properties corresponding to 1.4542, UNS 17400 and ASTM A564M
- Acid and corrosion resistant engineering parts
- Medical instruments (surgical tools, orthopedic instrumentation)
The EOS Quality Triangle
EOS incorporates these TRLs into the following two categories:
- Premium products (TRL 7-9): offer highly validated data, proven capability and reproducible part properties.
- Core products (TRL 3 and 5): enable early customer access to newest technology still under development and are therefore less mature with less data.
All of the data stated in this material data sheet is produced according to EOS Quality Management System and international standards
POWDER PROPERTIES
The chemical composition of parts is in compliance with standards “F899 – 12b Standard Specification for Wrought Stainless Steels for Surgical Instruments” and “A564M – 13 Standard Specification for Hot-Rolled and Cold-Finished AgeHardening Stainless Steel Bars and Shapes”. Composition complies the material composition in “powder properties” section. Part accuracy is adjustable by changing the “Beam Offset, X-, Y- and Z-Shrinkage”-parameters.
Powder Chemical Composition (wt.-%)
Element | Min. | Max. |
---|---|---|
Cr | 15 | 17.5 |
Ni | 3 | 5 |
Cu | 3 | 5 |
Si | - | 1 |
Mn | - | 1 |
C | - | 0.07 |
P | - | 0.04 |
S | - | 0.03 |
Nb + Ta | 0.15 | 0.45 |
Powder Particle Size
GENERIC PARTICLE SIZE DISTRIBUTION | 15 - 65 μm |
---|
HEAT TREATMENT
Vacuum H900 & Atmospheric HT procedures
Vacuum H900 heat treatment procedure
Solution annealing: Hold at 1040°C (1904°F) ±15°C (± 59°F) for 30 minutes, air cooling under 32°C (89°F).
Ageing: Hold at 480°C (896°F) for one hour, air cooling under 32°C (89°F).
Atmospheric HT procedure (preferred atmosphere: Argon)
Solution annealing: Hold at 1040°C (1904°F) ±15°C (± 59°F) for 30 minutes, air cooling under 32°C (89°F).
Ageing: Hold at 460°C (860°F) for one hour, air cooling under 32°C (89°F).